EUR

Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase

clay dredge pump installation

Sump pump discharge sizing

    amcclur

    I’m looking for a little advice on if I should upsize the discharge on my home’s sump pump. After upgrading the pump size it still can’t keep up, but only by the smallest of margins during absurd amount of rainfall. I’m making other improvements to prevent water making it to the sump pit but was wondering if upsizing the discharge line, which is an easy fix, would help in the meantime. The current setup is as follows:

    Pump: Flotec ½ HP 0 head = 4680 GPH 5 head = 4380 GPH 10 head = 3840 GPH 15 head = 3300GPH 20 head = 2340 GPH

    Discharge: 1 ½” PVC 10’ vertical run Single smooth 90 degree elbow 23’ horizontal run 20’ of 1 ½” corrugated discharge line

    What is the maximum discharge of the current setup and would upsizing to 2’ improve the output?

    bimr

    You might be able to get an additional 600 GPH if you upsize the line from 1.5-Inch to 2-Inch. What is really hurting you is the corrugated discharge line. Corrugated tubing has very bad hydraulic properties and much higher resistance to flow. It is not clear from your post where the 20' of 1 ½" corrugated discharge line is installed. So it is difficult to estimate the flow increase. In any case, I would replace the 20' of 1.5" corrugated discharge tubing with pipe.

    amcclur

    The solid PVC run includes the vertical to the basement ceiling and out to exterior wall, where it is connected to the 20' of 1 1/2" corrugated line on the exterior.

    chicopee

    Corrugated piping has at least twice the friction loss of smooth pipe. Assuming your piping is running full of water when the pump is energyzed, it appears that you are well outside the useful parameters of your pump.

    cvg

    For 1 1/2 inch line you are running about 7 - 8 fps. Drop your velocity to 3 or 4 fps and you can really reduce the friction loss in the pipe and fittings. you could go up to 2 1/2 inch and maximize your pump output. I wouldn't go any larger than that.

    DubMac

    If I'm reading your data correctly, you will never get MORE than 3840 gph out of your pump because it takes 10' to satisy the static or lift portion of your discharge head. You can look in a piping handbook to get the friction losses in your system now for various flows. Usually these losses will be in psi/100'ft. Of course 1psi=2.31 feet head. Just look at the difference in losses between 1-1/2" pipe and any larger size you want to install and make sure the difference is going to be worth the changeout.

    amcclur

    I concede I'm starting with 10' of head (3840 gph max), however would replacing the 1 1/2" PVC with 2 1/2" reduce the the friction loss significantly? I imagine I'm close to a 20' of head loss with the current setup, if not more. Not including the 20' of corrugated hose what would be the max output for my current setup? What would it be with 2 1/2" PVC? How large of an effect would replacing the corrugated with PVC have?

    BigInch

    If you tell us the flowrate you're getting now, we could tell you how much you can improve it. Otherwise the only thing we can say is that 3840 is an absolute maximum without any pipe loss included. From what you are saying, the present head loss is around 30 ft, and from what you ARE NOT saying, quessing a present flowrate of perhaps around 1500 gph, you may be able to as much as double that flow.

    bimr

    Here is a link for an online headloss calculator. Assuming the corrugated pipe is removed, use the calculator to estmate the pipe losses due to flow: @3840 gph 1.5-Inch pipe headloss = 6.4 Ft @3840 gph 2-Inch pipe headloss = 1.9 Ft @3300 gph 1.5 -Inch pipe headloss = 4.9 Ft So you are probably pumping approximately 3100-3200 gph (without the corrugated piece). If you replace with 2-Inch pipe, you can probably get 3400-3500 gph. If you go with 2.5-Inch pipe, you can probably get 3800 gph.

    amcclur

    Assuming a flow rate of 3600 gph would the head loss for the 20' of 1 1/2" corrugated section be ~8 feet?

    bimr

    Don't see a Hazen Williams factor for corrugated plastic. If you use the Hazen Williams factor for corrugated steel, the head loss for the 20' of 1 1/2-Inch corrugated section equates to 29.3 feet. I believe that you are using a factor of 120 which is for smooth wall plastic pipe and not appropriate for corrugated pipe.

  • Fast shipping
  • Home delivery
  • The promotion is underway
  • Free trial
  • 24/7 online
  • 30-day no-reason return policy
Contact us

Daniel Féau processes personal data in order to optimise communication with our sales leads, our future clients and our established clients.

Read more

Other related products

0 slurry pump body size

0 slurry pump body size

mud pump drawing

mud pump drawing

5 slurry pump wet end parts list

5 slurry pump wet end parts list

12 inch slurry pump drum

12 inch slurry pump drum

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.