This document provides information on the Sulzer Submersible Sewage Pump Type ABS XFP 80C - 201G. Key details include: - They are robust, submersible pumps for wastewater and sewage from 1.3 to 25.0 kW. For the pumping of wastewater and sewage from buildings and sites in private, commercial, industrial and municipal areas in accordance with EN 12050-1.
The water-pressure-tight, encapsulated, flood-proof motor and the pump section form a compact, robust, modular construction. NEMA Class A temperature rise. Premium Efficiency motors in accordance with IEC 60034-3 0 level IE3 with testing in accordance with IEC60034-2-1. Continuously rated motor in submerged and non-submerged applications. Double mechanical seals; SiC-SiC at the medium side, SiC-C at the motor. All seals are independent of rotation direction and resistant to temperature shock. Anti-wicking cable plug solution (80C - 150E), or water-pressure-sealed connection chamber (100G - 201G). Hydraulic options of Contrablock and Contrablock Plus impellers for high efficiency, or vortex impellers for maximum solids handling. Lubricated-for-l ife bearings with a calculated lifetime of minimum 50,000 hrs. (80C - 150E), and 100,000 hrs.(100G - 201G). Stainless steel shaft. Designed with high safety factor to prevent fatigue fracture. Temperature monitoring by thermal sensors (140 °C) in the stator windings. Seal monitoring by a moisture probe (DI) in the seal chamber(80C - 150E), or dry chamber (100G - 201G), which signals an inspection alert if there is leakage at the shaft seals. Smooth outer design to reduce rag build-up. Stainless steel lifting hoop. DN 80, DN 100, DN 150 and DN 200 radial slot DIN flange discharge. Maximum allowable temperature of the medium for continuous operation is 40 °C. Maximum submergence depth of 20 m. Explosion-proof as standard, in accordance with international standards Ex d IIB T4 and ATEX.
Premium Efficiency IE3, three-phase, squirrel-cage motor;400 V; 50 Hz; 2-pole (2900 r/min), 4-pole (1450) and 6-pole (980).Protection type IP 68, with stator insulation Class H.Start-up: 1.3 - 3.0 kW = direct on line (DOL)4.0 - 25.0 kW and 3.0 kW 6-pole = star-delta (YΔ).Service factor: 1.3 Motors with other operating voltages and frequencies are also available.
e.g. XFP 80C CB1.3 PE22/4-C-50 Hydraulics:XFP ........ Product range 8 ............ Discharge outlet DN (cm)0 . ...........Hydraulic type C ............ Volute opening (dia. mm)CB.......... Impeller type: CB = Contrablock, VX = vortex 1 ............ Number of impeller vanes 3 ............ Impeller size Motor:PE ......... Premium Efficiency 22 .......... Motor power P 2 kW x 10 4 ............ Number of poles C ............ Volute opening (dia. mm)50 .......... Frequency
Please use the ABSEL program as the only valid selection tool.