EUR

Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase

power plant fgd pump 10

Universal PCXR8 Pump

    Overview

    Universal PCXR8 Pump only, with programmable start/stop, NiMH battery, and screwdriver set (charger not included).

    Attributes

    Flow Rate: 5 to 5000 ml/min

    Touch Screen Operation: No

    Battery Type (Power): NiMH

    Approx. Run Time: 12+ Hours at 2 L/min

    Connectivity: No

    PC Compatible: No

    Programmable: Yes

    Compensates for Changes in Atmospheric Pressure: No

    Compensates for Changes in Temperature: No

    Constant Flow: Yes

    Constant Pressure Mode: No

    Automatic Flow Rate Verification: No

    Intrinsic Safety: Yes

    CE Marked: Yes

    UKCA Marked: Yes

    Specifications

    Flow Range 1000 to 5000 ml/min (UL Listed model) (5 to 500 ml/min requires the 224-26 Series adjustable tube holder) Requires 1/4-inch ID tubing

    Weight 34 oz (964 gm)

    Dimensions 5.1 x 4.7 x 1.9 in (13 x 11.9 x 4.8 cm)

    Compensation Range 1000 to 2500 ml/min at 40 inches water back pressure 3000 ml/min at 35 inches water back pressure 4000 ml/min at 20 inches water back pressure 5000 ml/min at 10 inches water back pressure

    Flow Control Holds constant flow to ± 5% of set-point

    Run Time NiCad Battery: 8 hrs minimum at 4000 ml/min and 20 inches water back pressure; dependent on media used. NiMH Battery: 12 hrs minimum at 4000 ml/min and 20 inches water back pressure; dependent on media used. Battery Eliminator: Pump will provide extended runs.

    Tubing Requires 1/4-inch ID tubing

    Timer Display Range 1 to 9999 minutes (6.8 days). Pump will shut off at 9999 minutes. To reset, restart the pump.

    Flow Indicator Built-in rotameter with 250-ml division; scale marked at 1, 2, 3, 4, and 5 L/min

    Charging Time 6 to 8.5 hrs with PowerFlex charger

    Power Supply 6-V plug-in NiMH battery pack, rechargeable, 3.5-Ah capacity or 6-V plug-in NiCad battery pack, rechargeable, 2.0-Ah capacity A battery eliminator is available

    Intrinsic Safety UL Listed for Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Temperature Code T3C

    Operating Temperature 32 to 104 F (0 to 40 C)

    Storage Temperature -4 to 113 F (-20 to 45 C)

    Charging Temperature 50 to 113 F (10 to 45 C)

    Operating Humidity 0 to 95% non-condensing

    Flow Fault If the pump is unable to compensate for longer than 15 seconds due to excessive back pressure, the pump enters flow fault. During flow fault, the pump stops, displays FLOW FAULT, pauses timing functions, and displays elapsed time or pump time. Auto-restart is attempted up to 5 times.

    Low Battery Fault Pumps stops, displays LO BATT, pauses timing functions, and displays elapsed time or pump time.

    Battery Test LCD indicator shows battery condition prior to sampling

    Time Display LCD displays up to 9999 minutes (6.8 days) at which point the display rolls over to 0. Displays include sampler run time in minutes for sampling period elapsed time, pump run time, or total elapsed time including delayed start

    Delay On Allows user to select minutes to delay start of test up to 9999 minutes (6.8 days)

    Timed Shutdown Allows user to select minutes of operation before automatic shutdown. Timed shutdown maximum is 9999 minutes (6.8 days)

    Timing Accuracy ± 0.05% (± 45 sec/day)

    Intermittent Sampling Programmable to allow user to extend short-term samples over an extended period of time to meet time-weighted average (TWA) requirements with a reduced number of samples. Elapsed time maximum is 9999 minutes (6.8 days), at which time the sample pump shuts down.

    Sampling Pause Allows user to temporarily halt sampling without loss of timing data. Restart does not require resetting time.

    Multiple-tube Sampling Built-in constant pressure regulator allows user to take up to four simultaneous samples with rates up to 500 ml/min each (total combined flow 1350 ml/min maximum) using the optional adjustable tube holder accessory

    RFI/EMI Shielding Complies with requirements of EN 55022, FCC Part 15 Class B, EN 50082-1 Frequency range of the radiated susceptibility test was 27 to 1000 MHz CE marked

    Additional Specifications Built-in particulate trap External see-through filter housing Tamper-resistant control cover Tamper-resistant compensation adjustments Built-in accessory mount Stainless steel belt clip External exhaust port All non-plastic parts made of corrosion-resistant materials RFI and EMI-shielded case

    Additional Features One-year warranty Ultra-quiet operation Pulsation-free flow Impact-resistant case

  • Fast shipping
  • Home delivery
  • The promotion is underway
  • Free trial
  • 24/7 online
  • 30-day no-reason return policy
Contact us

Daniel Féau processes personal data in order to optimise communication with our sales leads, our future clients and our established clients.

Read more

Other related products

x china water pump replacement

x china water pump replacement

a slurry pump wet end parts for sale

a slurry pump wet end parts for sale

e mini dredge pumps

e mini dredge pumps

vertical pump vibration limits

vertical pump vibration limits

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.