EUR
en
A submersible sewage pump is a specialist pump that sits fully underwater in a sewage pit, pump well or wastewater tank. It forms part of a wider family of wastewater pumps that manage both raw sewage and treated effluent in different stages of a property’s drainage system.
Some sites also use submersible sump pumps for stormwater, although these are usually a different pump type. In these cases, drainage pumps may be used alongside sewage pumps to manage groundwater or excess stormwater on the property. Its purpose is to handle raw sewage, liquid waste, solids, greywater or stormwater and move it from one location to another, usually uphill to a discharge line or sewer connection.
Unlike surface pumps, a submersible sewage pump is designed to be sealed completely, protecting the motor and internal components while it operates underwater. These pumps are used when gravity alone cannot move wastewater where it needs to go. The submerged operation of submersible pumps helps to dissipate heat generated by the motor, preventing overheating.
Common applications include:
These pumps play an important role in modern sewage systems by transferring waste from lower levels to points where gravity flow can resume.
Whenever waste water sits below a gravity-fed exit point, a submersible pump becomes essential. In some buildings a sump pump may also be installed nearby to manage groundwater or stormwater that collects around the foundation, working alongside the sewage pump to protect the property.
Submersible sewage pumps operate using a simple but highly effective principle: they convert electrical energy into mechanical energy, which creates the kinetic force needed to push sewage or wastewater up through a discharge pipe until it reaches the gravity line.
The design of submersible pumps minimises energy losses associated with suction lift, making them more energy-efficient than other pumps. This focus on energy efficiency is especially important for systems that operate frequently or manage high wastewater volumes.
Lower power consumption is a major advantage in sites where pumps cycle regularly or operate for extended periods.
Here is a step-by-step breakdown of how the process works.
Every submersible system begins with a collection basin or pit. Wastewater from toilets, sinks, showers and floor drains flows into this pit naturally through gravity. In some commercial or older combined systems, stormwater may also enter the pit, but this is not typical for most buildings. During heavy use or unexpected inflow, excess water can build up quickly in the pit, which is why the pump must activate reliably once the float reaches its trigger point.
The size of a pump pit can differ based on the type of property and the demands of the system. As a general guide:
Once the fluid reaches a certain height, the pump activates.
Submersible sewage pump systems use float switches to sense the level of liquid in the pit. These floats hang inside the pit and move up or down depending on the water level.
Most pits have:
As the pit fills, the float rises. When it reaches the activation point, the switch signals the pump to turn on.
Once the float triggers the system, the motor switches on. Commercial and industrial pumps vary widely in power output. Smaller units may start at a few kilowatts while larger solids-handling pumps can require significantly higher capacities depending on flow demands, pressure requirements, and the type of material being moved.
The motor is enclosed in a sealed housing with mechanical seals that prevent water entry, protect the wiring and keep the unit safe during underwater operation.
The motor’s shaft connects to the impeller, which rotates at high speed.
The impeller is the core of the pumping action. As it spins, it generates centrifugal force that pushes liquid outward into the pump volute and then into the discharge line. Submersible sewage pumps operate on the same principle as centrifugal pumps, using rotational energy to move wastewater efficiently through the system.
This centrifugal action is also used across many wastewater pumps that handle different waste streams in larger networks. However, unlike centrifugal pumps used in above-ground applications, a submersible unit performs the same process while operating fully underwater.
Different systems use different impeller designs. Vortex impellers handle large solids. Channel impellers offer efficient flow. Grinder pumps use a cutting mechanism to macerate sewage and deal with fibrous materials.
Each configuration is selected to move wastewater as reliably as possible.
Choosing the right impeller style also supports efficient operation, especially in systems that deal with varying flow rates or solids.
These designs also help the pump manage solid waste found in sewage, preventing clogs and keeping the system operating smoothly.
At this stage, the submersible wastewater pump forces the liquid upward through the discharge line. The pump forces wastewater up through a discharge pipe leading to a sewer main or onsite wastewater treatment system. Stormwater discharge applies only to sump pumps used for drainage, not sewage pumps. In basements or underground facilities, this pipe often rises several metres before connecting to a horizontal line where gravity takes over.
Once enough wastewater has been removed and the float drops to its off position, the pump stops. This prevents continuous running and protects the motor.
Whenever the water level rises, the pump activates again. This process prevents sewage overflow, protects the property and maintains a safe environment for occupants.
To operate safely and reliably, each sewage pump system includes several important components. Periodic inspection of seals and internal bearings is important for reliable operation, since seals protect the motor and bearings from water ingress.
This includes:
The housing is commonly made from cast iron or stainless steel, often with protective coatings. Some domestic units also use heavy-duty thermoplastic materials. These components must cope with harsh wastewater conditions, so many pump bodies and housings are built from corrosion resistant materials that handle long-term exposure to moisture, gases and abrasive solids. Investing in a pump with superior material and build quality ensures long-term performance and reliability.
The pit serves as the reservoir and provides room for floats. It must be sized correctly to prevent short cycling and premature wear.
These control the start, stop and high-level alarm functions. In larger systems, the control panel manages most logic while floats provide level-sensing inputs.
Quality pipework prevents blockages and handles pressure. PVC, stainless steel or HDPE is typically used. Pipework must be pressure-rated to handle vertical lift and flow. PVC, stainless steel or HDPE are commonly used depending on the application.
This prevents wastewater from flowing back into the pit after pumping.
Guide rail systems are common in commercial stations and many dual-pump residential systems, allowing the pump to be lifted out for servicing without entering the pit.
Larger systems use a dedicated control panel for power management, circuit protection, alarms and optional telemetry. In dual-pump systems, the panel also alternates duty between pumps.
High-level alarms notify managers or residents when the pit level becomes too high. Alerts may include audible alarms, visual indicators or remote notifications.
Understanding the main pump types helps support proper pump selection.
Move large solids with minimal clogging. Ideal for raw sewage and sludge where solids handling is important. They are one of the most reliable ways to pump raw sewage in systems that need strong solids-handling capabilities.
Macerate solids into a fine slurry. Used in pressure sewer systems or applications that require long discharge runs or higher head pressure.
Use rotating blades to break down fibrous materials such as wipes or cloth. Commonly used in commercial and light industrial sites.
Efficient for high-flow applications with low-to-moderate solids, often used in commercial buildings.
Used for stormwater, groundwater or dirty water that does not contain large solids. These pumps are not suitable for heavy sewage or waste with larger debris.
Some properties also rely on sewage ejector pumps, which perform a similar function by lifting waste to a sewer line when gravity flow is not possible. Choosing between these systems is important because selecting the wrong pump type increases maintenance, breakdowns and operational costs.
Submersible pumps are built for demanding environments. Their reliability comes from:
These features allow submersible pumps to run safely underwater, even in wastewater containing corrosive gases and debris.
Many commercial and industrial setups require continuous operation, so reliability and component durability are critical.
Even high-quality pumps eventually wear out, but most failures can be prevented.
Common causes include:
Failures often occur during storms or peak flow events when the pump has not been maintained.
A submersible sewage pump should never be left to“run until it breaks.”A failure can result in:
Proper maintenance helps prevent most of these issues.
A well-maintained pump keeps waste water moving safely and reduces emergency breakdowns. Doing maintenance on a regular basis also ensures optimal performance as the system ages or operating conditions change.
Reduce flood risk in underground car parks and plant rooms.
Manage wastewater from amenities and high-use areas.
Handle trade waste, high-volume wastewater systems and the demanding conditions often found in industrial settings.
Temporary pump setups often support drainage, manage runoff and control wastewater during active building work.
Support basement bathrooms, granny flats and rural properties, including septic tank systems that need effluent pumped to a raised disposal area.
Common in many sewer pumping stations and municipal wastewater systems.
These environments require consistency, reliability and compliance, making professional servicing a non-negotiable.
Selecting the wrong pump leads to:
Key factors to consider:
A professional assessment helps confirm that the correct pump is installed from the start.
Submersible sewage pumps keep waste water moving safely in homes, strata buildings and commercial sites. They work by converting electrical energy into mechanical energy, which spins the impeller and creates the centrifugal force needed to push liquid and solids up through a discharge line until it reaches a gravity connection or rising main. With robust impellers, sealed motors, reliable float systems and, in larger systems, smart control panels, these pumps are built for demanding conditions.
However, even high-quality pumps need regular maintenance to maintain performance, prevent emergencies and extend service life. Pump failure can lead to costly and disruptive overflow, especially in basements and strata settings. Common issues include clogging, float switch failure, overheating from dry running and electrical or motor faults.
Bookmark
Daniel Féau processes personal data in order to optimise communication with our sales leads, our future clients and our established clients.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.