EUR

Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase
Excellent supplier product showcase

slurry booster pump kit

CM20180103-31966-27234

    Output Ratings

    Voltage, Frequency Prime Standby 400/230 V, 50 Hz kVA 230 250 kW 184 200 kVA kW Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.

    Dimensions and Weights

    Length mm 2662 (104.8) Width mm 1071 (42.2) Height mm 1818 (71.6) Weight (Dry) kg 2035 (4486) Weight (Wet) kg 2068 (4559) Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Generator set pictured may include optional accessories.

    Prime Rating

    These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

    Standby Rating

    These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

    Standard Reference Conditions

    Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

    Standard Alternator Ratings and Performance Data

    Engine Make Perkins Engine Model: 1506A-E88TAG2 Alternator Make Leroy Somer Alternator Model: LL5114H Control Panel: DSE7410 Base Frame: Heavy Duty Fabricated Steel Circuit Breaker Type: 3 Pole MCCB Frequency: 50 HZ 60 HZ Engine Speed: RPM rpm 1500 Fuel Tank Capacity: litres (US gal) 528 (139.48) Fuel Consumption Prime litres (US gal)/hr 47.2 (12.5) Fuel Consumption Standby litres (US gal)/hr 50.7 (13.4)

    Engine Technical Data

    No. of Cylinders 6Alignment IN LINE Cycle 4 STROKE Bore mm (in) 112 (4.4) Stroke mm (in) 149 (5.9) Induction TURBOCHARGED AIR TO AIR CHARGE COOLED Cooling Method WATER Governing Type ELECTRONIC Governing Class ISO 8528 G2 Compression Ratio 16.1:1 Displacement L (cu. in) 8.8 (537) Moment of Inertia: kg m² (lb/in²) 2.4031 (8212) Voltage 24 Ground Negative Battery Charger Amps 45 Engine Weight Dry kg (lb) 778 (1715) Engine Weight Wet kg (lb) 800 (1764)

    Engine Performance Data 50 Hz 60 Hz

    Engine Speed rpm 1500 Gross Engine Power Prime kW (hp) 213 (286) Gross Engine Power Standby kW (hp) 236 (316) BMEP Prime kPa (psi) 1935 (280.6) BMEP Standby kPa (psi) 2144 (310.9)

    Fuel System

    Fuel Filter Type: Replaceable Element Recommended Fuel: Class A2 Diesel Fuel Consumption at 110 % Load 100 % Load 75 % Load 50 % Load 50 Hz Prime: l/hr (US gal/hr) 50.7 (13.4) 47.2 (12.5) 36.4 (9.6) 24.5 (6.5) 50 Hz Standby l/hr (US gal/hr) - 50.7 (13.4) 39.3 (10.4) 26.6 (7) 60 Hz Prime l/hr (US gal/hr) 60 Hz Standby l/hr (US gal/hr) -(Based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, class A2

    Air System 50 Hz 60 Hz

    Air Filter Type: Paper Element Combustion Air Flow Prime m³/min (cfm) 14.4 (509) Combustion Air Flow Standby m³/min (cfm) 15 (530) Max. Combustion Air Intake Restriction kPa 6.2 (24.9)

    Cooling System 50 Hz 60 Hz

    Cooling System Capacity l (US gal) 30.7 (8.1) Water Pump Type: Centrifugal Heat Rejected to Water & Lube Oil: Prime kW (Btu/min) 93 (5289) Heat Rejected to Water & Lube Oil: Standby kW (Btu/min) 99 (5630) Heat Radiation to Room*: Prime kW (Btu/min) 29 (1649) Heat Radiation to Room*: Standby kW (Btu/min) 30.3 (1723) Radiator Fan Load: kW (hp) 7.7 (10.3) Radiator Cooling Airflow: m³/min (cfm) 329.1 (11624) External Restriction to Cooling Airflow: Pa (in H2O) 125 (0.5) *: Heat radiated from engine and alternator Designed to operate in ambient conditions up to 50°C (122°F). Contact your local FG Wilson Dealer for power ratings at specific site conditions.

    Lubrication System

    Oil Filter Type: Spin-on, Full flow Total Oil Capacity: l (US gal) 39 (10.3) Oil Pan Capacity: l (US gal) 36 (9.5) Oil Type: API CI-4 0W-30 Oil Cooling Method: WATER

    Exhaust System 50 Hz 60 Hz

    Maximum Allowable Back Pressure: kPa (in Hg) 10 (3) Exhaust Gas Flow: Prime m³/min (cfm) 34.4 (1215) Exhaust Gas Flow: Standby m³/min (cfm) 35.7 (1261) Exhaust Gas Temperature: Prime °C (°F) 467 (873) Exhaust Gas Temperature: Standby °C (°F) 475 (887)

    Alternator Physical Data

    No. of Bearings: 1Insulation Class: HWinding Pitch: 2/3 Winding Code 6Wires: 12 Ingress Protection Rating: IP23 Excitation System: SHUNT AVR Model: R250 * dependant on voltage code selected

    Alternator Operating Data

    Overspeed: rpm 2250 Voltage Regulation: (Steady state) % +/- 0.5 Wave Form NEMA = TIF: 50 Wave Form IEC = THF: % 2Total Harmonic content LL/LN: % 2Radio Interference: EN61000-6 Radiant Heat: 50 Hz kW (Btu/min) 16.3 (927) Radiant Heat: 60 Hz kW (Btu/min)

    Alternator Performance Data 50 Hz:

    Voltage Code 415/240 V 400/230 V 380/220 V 230/115 V 230 V Motor Starting Capability* kVA 563 532 491 Short Circuit Capacity** % 300 300 300 300 Reactances Xd 3.517 3.786 4.195 X’d 0.244 0.262 0.291 X”d 0.155 0.155 0.172

    Alternator Performance Data 60 Hz

    Voltage Code Motor Starting Capability* kVA Short Circuit Capacity** % 300 300 300 300 300 Reactances Xd X’d X”d Reactances shown are applicable to prime ratings. *Based on 30% voltage dip at 0.6 power factor. ** With optional independant excitation system (PMG / AUX winding)

    Output Ratings 50 Hz

    Prime Standby Voltage Code kVA kW kVA kW 415/240V 230 184 250 200 400/230V 230 184 250 200 380/220V 230 184 250 200 230/115V 230 184 250 200 220/127V 220/110V 200/115V 240V 230V 220V

    Output Ratings 60 Hz

    Prime Standby Voltage Code kVA kW kVA kW 480/277V 440/254V 416/240V 400/230V 380/220V 240/139V 240/120V 230/115V 220/127V 220/110V 208/120V 240/120 220/110

    Documentation

    Operation and maintenance manual including circuit wiring diagrams.

    Generator Set Standards

    The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22.

    Warranty

    The warranty for this product in prime applications is 12 months from date of start-up, unlimited hours (8760). For standby applications the warranty period is 24 months from date of start-up, limited to 500 hours per year.

    CM20180103-31966-27234******

    FG Wilson manufactures product in the following locations: Northern Ireland • Brazil • China • India With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network. To contact your local Sales Office please visit the FG Wilson website at www.fgwilson.com. FG Wilson is a trading name of Caterpillar (NI) Limited. In line with our policy of continuous product development, we reserve the right to change specification without notice. 2022-10-12

  • Fast shipping
  • Home delivery
  • The promotion is underway
  • Free trial
  • 24/7 online
  • 30-day no-reason return policy
Contact us

Daniel Féau processes personal data in order to optimise communication with our sales leads, our future clients and our established clients.

Read more

Other related products

residential sewage grinder pump system

residential sewage grinder pump system

e limestone slurry pumps

e limestone slurry pumps

rubber mud pump

rubber mud pump

2 inch slurry pump calculations

2 inch slurry pump calculations

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.