EUR
en
Voltage, Frequency Prime Standby 400/230 V, 50 Hz kVA 230 250 kW 184 200 kVA kW Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.
Length mm 2662 (104.8) Width mm 1071 (42.2) Height mm 1818 (71.6) Weight (Dry) kg 2035 (4486) Weight (Wet) kg 2068 (4559) Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22. Generator set pictured may include optional accessories.
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).
Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
Engine Make Perkins Engine Model: 1506A-E88TAG2 Alternator Make Leroy Somer Alternator Model: LL5114H Control Panel: DSE7410 Base Frame: Heavy Duty Fabricated Steel Circuit Breaker Type: 3 Pole MCCB Frequency: 50 HZ 60 HZ Engine Speed: RPM rpm 1500 Fuel Tank Capacity: litres (US gal) 528 (139.48) Fuel Consumption Prime litres (US gal)/hr 47.2 (12.5) Fuel Consumption Standby litres (US gal)/hr 50.7 (13.4)
No. of Cylinders 6Alignment IN LINE Cycle 4 STROKE Bore mm (in) 112 (4.4) Stroke mm (in) 149 (5.9) Induction TURBOCHARGED AIR TO AIR CHARGE COOLED Cooling Method WATER Governing Type ELECTRONIC Governing Class ISO 8528 G2 Compression Ratio 16.1:1 Displacement L (cu. in) 8.8 (537) Moment of Inertia: kg m² (lb/in²) 2.4031 (8212) Voltage 24 Ground Negative Battery Charger Amps 45 Engine Weight Dry kg (lb) 778 (1715) Engine Weight Wet kg (lb) 800 (1764)
Engine Speed rpm 1500 Gross Engine Power Prime kW (hp) 213 (286) Gross Engine Power Standby kW (hp) 236 (316) BMEP Prime kPa (psi) 1935 (280.6) BMEP Standby kPa (psi) 2144 (310.9)
Fuel Filter Type: Replaceable Element Recommended Fuel: Class A2 Diesel Fuel Consumption at 110 % Load 100 % Load 75 % Load 50 % Load 50 Hz Prime: l/hr (US gal/hr) 50.7 (13.4) 47.2 (12.5) 36.4 (9.6) 24.5 (6.5) 50 Hz Standby l/hr (US gal/hr) - 50.7 (13.4) 39.3 (10.4) 26.6 (7) 60 Hz Prime l/hr (US gal/hr) 60 Hz Standby l/hr (US gal/hr) -(Based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, class A2
Air Filter Type: Paper Element Combustion Air Flow Prime m³/min (cfm) 14.4 (509) Combustion Air Flow Standby m³/min (cfm) 15 (530) Max. Combustion Air Intake Restriction kPa 6.2 (24.9)
Cooling System Capacity l (US gal) 30.7 (8.1) Water Pump Type: Centrifugal Heat Rejected to Water & Lube Oil: Prime kW (Btu/min) 93 (5289) Heat Rejected to Water & Lube Oil: Standby kW (Btu/min) 99 (5630) Heat Radiation to Room*: Prime kW (Btu/min) 29 (1649) Heat Radiation to Room*: Standby kW (Btu/min) 30.3 (1723) Radiator Fan Load: kW (hp) 7.7 (10.3) Radiator Cooling Airflow: m³/min (cfm) 329.1 (11624) External Restriction to Cooling Airflow: Pa (in H2O) 125 (0.5) *: Heat radiated from engine and alternator Designed to operate in ambient conditions up to 50°C (122°F). Contact your local FG Wilson Dealer for power ratings at specific site conditions.
Oil Filter Type: Spin-on, Full flow Total Oil Capacity: l (US gal) 39 (10.3) Oil Pan Capacity: l (US gal) 36 (9.5) Oil Type: API CI-4 0W-30 Oil Cooling Method: WATER
Maximum Allowable Back Pressure: kPa (in Hg) 10 (3) Exhaust Gas Flow: Prime m³/min (cfm) 34.4 (1215) Exhaust Gas Flow: Standby m³/min (cfm) 35.7 (1261) Exhaust Gas Temperature: Prime °C (°F) 467 (873) Exhaust Gas Temperature: Standby °C (°F) 475 (887)
No. of Bearings: 1Insulation Class: HWinding Pitch: 2/3 Winding Code 6Wires: 12 Ingress Protection Rating: IP23 Excitation System: SHUNT AVR Model: R250 * dependant on voltage code selected
Overspeed: rpm 2250 Voltage Regulation: (Steady state) % +/- 0.5 Wave Form NEMA = TIF: 50 Wave Form IEC = THF: % 2Total Harmonic content LL/LN: % 2Radio Interference: EN61000-6 Radiant Heat: 50 Hz kW (Btu/min) 16.3 (927) Radiant Heat: 60 Hz kW (Btu/min)
Voltage Code 415/240 V 400/230 V 380/220 V 230/115 V 230 V Motor Starting Capability* kVA 563 532 491 Short Circuit Capacity** % 300 300 300 300 Reactances Xd 3.517 3.786 4.195 X’d 0.244 0.262 0.291 X”d 0.155 0.155 0.172
Voltage Code Motor Starting Capability* kVA Short Circuit Capacity** % 300 300 300 300 300 Reactances Xd X’d X”d Reactances shown are applicable to prime ratings. *Based on 30% voltage dip at 0.6 power factor. ** With optional independant excitation system (PMG / AUX winding)
Prime Standby Voltage Code kVA kW kVA kW 415/240V 230 184 250 200 400/230V 230 184 250 200 380/220V 230 184 250 200 230/115V 230 184 250 200 220/127V 220/110V 200/115V 240V 230V 220V
Prime Standby Voltage Code kVA kW kVA kW 480/277V 440/254V 416/240V 400/230V 380/220V 240/139V 240/120V 230/115V 220/127V 220/110V 208/120V 240/120 220/110
Operation and maintenance manual including circuit wiring diagrams.
The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22.
The warranty for this product in prime applications is 12 months from date of start-up, unlimited hours (8760). For standby applications the warranty period is 24 months from date of start-up, limited to 500 hours per year.
Bookmark
Daniel Féau processes personal data in order to optimise communication with our sales leads, our future clients and our established clients.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.