A check valve on a sump pump is crucial for preventing backflow of water into the sump pit after the pump shuts off. Here’s exactly where and how to place it:
Install the check valve on the discharge pipe, just above the sump pump, but below the basement floor level or first pipe bend.
Orientation Matters: Ensure the arrow on the valve body points away from the pump, indicating water flow direction. Use Unions or Rubber Couplings: These make it easy to remove the valve for maintenance. Leave Vertical Pipe Space: Leave at least 8–12 inches of straight vertical pipe between the pump and the valve, if possible, to prevent turbulence. Quiet Check Valves (Optional): Consider a “quiet” or spring-loaded check valve to reduce clunking noises when the valve shuts.
Directly on the pump outlet—leave some vertical pipe. Above floor level—water can drain back down the pipe and cause the pump to cycle unnecessarily.
Here are the most common mistakes people make when installing or using check valves on sump pumps, and how to avoid them:
Mistake: The valve is installed in the wrong flow direction, causing no water to leave the pit. Fix: Follow the arrow on the valve body, which should point away from the pump (toward the discharge line).
Mistake: Placing the check valve far above the sump pit allows a large volume of water to drain back when the pump shuts off. Fix: Install the check valve just above the pump, ideally 8–12 inches above the discharge port.
Mistake: Omitting a check valve leads to backflow into the pit, causing the pump to cycle repeatedly and wear out faster. Fix: Always install a check valve on the vertical discharge line.
Mistake: Using a swing check valve in a high-flow system can cause loud “water hammer” noises. Fix: Use a spring-loaded or quiet check valve if noise or water hammer is a concern.
Mistake: Leaky or improperly sealed joints around the valve may lead to water spray or air leaks. Fix: Use rubber couplings with hose clamps or PVC glue (if using rigid PVC) to ensure a tight, sealed fit.
Mistake: Installing the valve in a hard-to-reach place makes it difficult to service. Fix: Use union fittings or quick-release clamps for easy removal and cleaning.
Mistake: Installing the valve at an angle can cause it to not close properly, allowing backflow. Fix: Install the valve vertically for proper function.
Mistake: A poorly vented line can allow air to get trapped, reducing pump efficiency. Fix: Ensure there’s an air relief hole in the pump’s discharge pipe or in the pump housing, if recommended by the manufacturer.